气体定压比热表

                                                     《焚烧炉设计资料》

 主要排气0~t℃间的平均定压比热(Cp)值    单位:kcal/Nm3

t ℃

O2

N2

CO2

CO

NO

SO2

水蒸汽

空气

HCl

Cl2

100

0.315

0.311

0.409

0.312

0.319

0.435

0.360

0.311

0.311

0.369

200

0.320

0.312

.429

.313

.321

.454

.364

.313

.311

.374

300

.325

.313

.447

.316

.323

.470

.369

.315

.313

.379

400

.330

.316

.463

.319

.327

.483

.374

.318

.315

.382

500

.334

.319

.477

.322

.330

.495

.380

.321

.317

.384

600

.339

.321

.490

.326

.334

.506

.386

.325

.320

.386

700

.343

.325

.501

.329

.337

.515

.392

.328

.322

.388

800

.347

.329

.512

.332

.340

.523

.399

.331

.324

.389

900

.350

.331

.520

.335

.344

.530

.405

.334

.327

.391

1000

.354

.334

.529

.338

.346

.536

.412

.338

.329

.392

1100

.356

.338

.537

.341

.349

.542

.418

.340

 

.393

1200

.359

.340

.544

.344

.351

..546

.425

.343

 

.394

1300

.362

.342

.550

.346

.354

.550

.430

.345

 

 

1400

.364

.345

.556

.348

.356

.554

.437

.348

 

 

1500

.366

.347

.561

.351

.358

.557

.442

.350

 

 

1600

.368

.350

.567

.353

.360

.560

.448

.353

 

 

1700

.370

.351

.571

.355

.362

.563

.454

.354

 

 

1800

.372

.353

.575

.356

.363

.566

.459

.356

 

 

1900

.374

.354

.579

.358

.365

.567

.464

.358

 

 

2000

.375

.356

.583

.359

.366

.570

.469

.359

 

 

分子量

32.00

28.02

44.01

28.00

30.00

64.06

18.02

28.964

36.5

71.00

系数

0.7

0.8

0.509

0.8

0.747

0.35

1.244

0.772

0.615

0.315

Cp(kcal/kg℃)= kcal/Nm3℃×系数

 宜兴市中环焚烧设备有限公司--技术部 注:本表供参!

 

金博棋牌1.1.6版本久六郑州棋牌 document.writeln("");